Commercial High Temperature Heat Pump T5-F Series

Commercial High Temperature Heat Pump T5-F Series

Water Temperature Reach Up To 80℃

Strong inner

American COPELAND special compressor, apply R134a refrigerant, stable operation and high efficiency.

Easy operation

LCD operation panel, running at a glance, real-time control of hot water, real-time control the best demand.

Easy maintenance

Independent maintenance space design; Simplify maintenance process; intelligent detaction and fault self-check function.

Constant temperature water output

Coordinated control of water replenishing by temperature and liquid level; Keep the water temperature constant in the preservation water tank; The water temperature can goes up to 80℃.

Excellent configuration, durable quality

American brand COPELAND special compressor

High efficiency shell and tube heat exchanger

Famous brand electomic expansion valve

Hydrophilic aluminum foil fins evaporator

Thickened galvanized plate, can anti-corrosion and durable.

Applicable places: drying room, slaughterhouse, greenhouse planting, sauna and other places.

Commercial High Temperature Heat Pump T5-F Series Installation Diagram:

Commercial High Temperature Heat Pump T5-F Series Installation Diagram

Remark:

1. Make sure there is suffcient water in the water tank for the function of the unit just before debugging (open all the valves, the water level in the water tank should be higher than the circulation inlet), the outlet for hot water should be at least 10cm higher than the circulation inlet in the bottom in case that there is no water in circulation system.

2. Refer to the diagram ablove when you need to install water-replenishment pipes, The standard fittings as: water Replenishment solenoid valve(220V, normally close)、water flow switch、 water level tower、stainless steel strip and floating ball and so on . Pay more attention to the points below when installing; 

3. Add water Replenishment by-pass valve and install floating ball in the pipe in order to replenish water automatically when replenishment valve  doesn't work.

4. We suggest placing the low water level wire on top of hot water outlet of the water tank, about 10cm high than the outlet.

Commercial High Temperature Heat Pump T5-F Series Specifications

Model

Input Power

(kW)

Current

(A)

Voltage

(V)

Heating Capacity

(kW)

Circulating Water Volume

(T/h)

Output water temperature

(℃)

Pressure drop

(kPa)

Hot water output

(L/H)

Connection pipe size

(DN)

Unit size

(㎜)

Net Weight

(kg)

Noise

(dBA)

RS-11GX 2.0 3.5 380 7.5 1.3 55 38 161 25 710×710×765 105 58
RS-18GX 3.5 6.0 380 13.0 2.2 55 40 280 25 765×765×950 130 60
RS-36GX 7.0 12.0 380 26.0 4.5 55 48 559 40 1450×705×1190 280 65